User Manual - Modbus Slave Protocol Library - ‘C’ Source Code
1 Architecture. 4
1.1 MSPL Block
Schematic. 4
1.2 Directory
Structure. 5
1.3 Files. 5
1.4 Hooks and Macros. 6
2 Porting. 6
2.1 Add source code
to your project. 7
2.2 Set Endian
Architecture. 7
2.2.1 More about
Endianness. 8
2.3 Select Modbus
framing type (RTU or TCP). 9
2.4 Glue MSPL to
device interface. 9
2.4.1 Supporting
Modbus communication on multiple channels. 10
2.4.2 Supporting
multiple Modbus TCP connections in MSPL-C. 10
2.5 Glue MSPL-C to
application and database. 11
2.5.1 Glue library to
Application. 11
2.5.2 Glue library to
simulated Database. 11
2.5.3 Using the Data
Formatter to map ‘C’ data types to Modbus. 12
2.6 Configure
diagnostics. 13
2.6.1 Step-1: Select
debugger level 14
2.6.2 Step-2: Include
or exclude Formatted I/O support. 14
2.6.3 Step-3:
Implement the debug “sink”. 15
2.7 Optimise MSPL-C. 15
2.7.1 Set optimal
buffer sizes. 16
2.7.2 Enable only the
function codes you require. 17
2.7.3 Reduce Code
Memory size by excluding support for message counters. 17
2.7.4 Reduce Code
Memory size by configuring CRC macros (Modbus RTU only). 18
2.7.5 Reduce Data
Memory (RAM) size by configuring CRC macros. 18
2.8 Build and test
your port with the supplied Modbus Protocol Tester. 19
2.8.1 Modbus Protocol
Tester - Overview.. 19
2.8.2 Installing
Modbus Protocol Tester. 19
2.8.3 Help on using
Modbus Protocol Tester. 20
3 Making calls into
MSPL-C APIs. 21
3.1 Flowchart for
MSPL-C API invocation. 22
4 MSPL-C Configurator
for easy configuration of the library. 23
4.1 How to use the
MSPL-C Configurator. 23
4.2 MSPL-C
Configurator Settings. 24
5 Using MSPL-C in a
multitasking environment. 26
6 MSPL-C Reference. 27
6.1 MSPL-C Data Types. 27
6.2 MSPL-C Function
Reference. 28
6.2.1 MSPL_UserInit. 28
6.2.2 MSPL_UserDeInit. 28
6.2.3 MSPL_OpenPort. 28
6.2.4 MSPL_ClosePort. 29
6.2.5 MSPL_CheckSlaveId. 29
6.2.6 MSPL_ValidateAddresses. 30
6.2.7 MSPL_ReadUserData. 30
6.2.8 MSPL_WriteUserData. 31
6.2.9 MSPL_ReadPort. 32
6.2.10 MSPL_WritePort. 33
6.2.11 MSPL_DebugPrint. 33
6.2.12 MSPL_RunModbus. 35
6.2.13 Status codes
returned by function MSPL_RunModbus. 35
6.2.14 MSPL_GetMessageCounters. 36
6.3 Macro Reference. 38
6.3.1 MODBUS_MODE. 38
6.3.2 ENDIAN_STYLE. 38
6.3.3 Macros for
exclusion of unsupported Modbus functions. 38
6.3.4 INCLUDE_MSG_CTRS. 38
6.3.5 RD_BLK_SIZE_BITINFO.. 39
6.3.6 RD_BLK_SIZE_REGINFO.. 39
6.3.7 WR_BLK_SIZE_BITINFO.. 39
6.3.8 WR_BLK_SIZE_REGINFO.. 40
6.3.9 RX_BUFFER_SIZE
and TX_BUFFER_SIZE. 40
6.3.10 STDIO_SUPPORTED.. 40
6.3.11 FORMATTED_STRING_PRINT. 41
6.3.12 DEBUG_LEVEL. 41
6.3.13 DEBUG_COLSIZE. 42
6.3.14 CRC_TABLE_LOCATION.. 42
6.3.15 CRC_TABLE_LOC_MODIFIER. 42
6.3.16 DATA_IN_XRAM... 43
6.3.17 MAX_NETWORKS. 43
Key architectural principles:-
·
Simplicity – to reduce code size
·
Maximum portability - Strict compliance to ANSI ‘C’ standards
·
Robust - only static memory allocation
·
Sparing use of code and memory
·
Modular, scalable and configurable – easy to maintain
·
Easy to debug
Back to the top
Modbus Slave Library: components, organization, and
interconnections.

Components of the library:
|
S.No.
|
Module
|
Functionality
|
File Name
|
|
1
|
MSPL Core
|
Frame Parsing
Packet Generation
Deploy Modbus Functions
Multi-level debugger
|
MSPC_C.c
|
|
2
|
Formatter
|
Data formatter. Modbus data types converted to:-
Short Integer
Integer
Float
String
|
CSPL_Utils.c
|
|
3
|
Porting Module
|
Links source code library to physical device and user
application.
|
MSPL_UserIF.c
This file modified by user
|
Back to the top
Folders within MSPL-C package:-

|
Folder Name
|
Contents
|
Remarks
|
|
Configurator
|
MSPL-C Configurator
|
GUI based MSPL-C Configurator to set parameters
such as buffer size, Endian type
|
|
Documents
|
MSPL-C User’s Manual
|
|
|
Library
|
Source files of MSPL-C
|
The files in this folder have the user definable hook
functions left empty.
|
|
License
|
license agreement for the version of the library purchased
|
The license agreement has a unique license number which
must be used in all correspondences with Colway Solutions regarding this library.
|
|
MPT
|
Installer for Modbus Protocol Tester
|
You will use this utility to test your port of the MSPL-C.
See section 2.9 for more on MPT.
|
|
Ports
|
Ports of MSPL-C to Win32 and any other platform you
requested.
|
The Win32 port can be found in “Ports\Win32”
folder. This port contains project files to compile the source in MS Visual
Studio 2008. If you requested for any other ports in addition to Win32, a
relevant folder will also be included.
|
Back to the top
The Modbus Slave Protocol Library contains the following
‘C’ source files:
|
File Type
|
Filename
|
Contents
|
Engineer Modifies ?
|
|
‘C’ Source
|
MSPL_C.c
|
Modbus communication protocol stack
|
No
|
|
CSPL_Utils.c
|
Library utility functions. Used by application too.
Formatter
|
No
|
|
MSPL_UserIf.c
|
Platform dependent functions implemented by user “stubs”
to receive platform dependent code. Refer to Win32 port for example.
|
Yes.
|
|
‘C’ header
|
MSPL_C.h
|
Header file for MSPL_C.c
|
No
|
|
CSPL_Utils.h
|
Header file for CSPL_Utils.c
|
No
|
|
CSPL_MbDefs.h
|
Colway Solutions type and symbol definitions for maximum
portability.
CSPL_U16
CSPL_U132
etc.
|
Yes. Review and change for specific target
|
|
MSPL_UserIf.h
|
Default values for all parameters.
Refer to Win32 port for example
|
Yes. Extensive modification to complete port
|
Add MSPL files to your project
After creating your project in the IDE of your platform, you
must add all the files above into this project and if required explicitly
configure all the above source files to be included in the build process.
Back to the top
Hooks
·
The porting of MSPL-C to a new platform is accomplished by means
of defining hook functions.
·
The hook functions are left unimplemented in the library
·
Hook functions need to be implemented for porting the library
Macros
·
‘C’ macros created using #define pre-processor statement
·
Control conditional inclusion or exclusion of portions of the
library code
·
Define values for configuration parameters
Back to the top
2
Porting
The following steps are required to port the Modbus Slave
Protocol Library to your hardware and software environment.
Step
1. Add MSPL-C
files to your project
Step
2. Define the
Endian Architecture of your platform
Step
3. Select
Modbus framing type (RTU or TCP)
Step
4. Glue
MSPL-C to the physical interface of your platform
Step
5. Glue
MSPL-C to the your application’s database
Step
6. Configure
diagnostics
Step
7. Optimise
MSPL-C
Step
8. Build and
test your port with the supplied Tester
Back to
the top
The first step in using MSPL-C is to add its source files to
your project. The procedure for this step differs from one compiler or IDE to
other. The following section describes this procedure with relevant screen
shots for the Silicon Laboratories IDE. Procedure for other IDE’s will be
similar.
i.
Create a new group called “MSPL” by right-clicking on the project name and
choosing “Add Groups to project <proj name>” as shown below. Note that
this step is optional.
ii. Right-click the
mouse on the MSPL group created above. If the above step was skipped,
right-click on any other group to which you intend to add MSPL-C files. Click
on item “Add file to group <group name>”. A File Open dialog box appears.
iii.
Browse to the folder containing the MSPL-C files and select all .c files. Click
“Open”.
iv. Press and hold the CTRL key
and select all .c MSPL files. Right-click and choose “Add to build”. This step
is necessary to include the MSPL-C files in the compilation and build process.

Back to the top
Modbus follows the Big Endian byte ordering system.
Therefore the byte ordering has to be reversed if the Modbus library is
deployed on a Little Endian processor. The library has a macro ENDIAN_STYLE,
used to set the correct Endian characteristic.
Steps
a) Open file
MSPL_UserIf.h
b) Locate the definition
of macro ENDIAN_STYLE
c) If your platform
is Little Endian, change the above macro’s value to LITTLE_ENDIAN. If it
is Big Endian, change the macro’s value to BIG_ENDIAN. The modified line
should look like this:
#define ENDIAN_STYLE LITTLE_ENDIAN /* for Little Endian */
#define ENDIAN_STYLE BIG_ENDIAN /* for Big Endian */
d) Rebuild your project
and test.
Notes
·
The utility functions provided by the Formatter (e.g. MSPL_ShortIntsToBuffer)
are “Endian-aware” – they are programmed check and ensure that transfers from
interpreted data types to raw buffers conform to Endianess of the platform.
·
If you use your own code for such transfers, remember to address
the issue of Endianess. Raw data in a Modbus packet is always in Big Endian
format.
·
To know the Endianess of your platform, refer to the User Manual
of your processor.
·
If you are unsure of the Endianess of your platform, a simple
technique to determine this is to create a ‘C’ program with an unsigned short
int variable (16-bit) and store the value 0xABCD in it:
unsigned short int testVar = 0xABCD;
Then debug this program and see
the memory contents (using a Memory Dump or Memory Watch window) at the
location of this variable. If you find 0xAB stored first and then 0xCD, you
have a Big Endian system, else you have a Small Endian system.
Back to the top
Endianness is the byte (and sometimes bit) ordering used to
represent some kind of data.
Also referred to as byte order.
For example a ‘C’ variable of data type float consists
of four bytes. There are variations in storage sequence of these four bytes among
different systems.
Endianess is crucial in communication systems
implementation. Need to ensure that data reaches destination in the correct
byte order.
Two most commonly used byte ordering systems are:
·
Big Endian. Most significant byte of data unit is stored
first in memory followed by the rest in descending order of significance.
Motorola 68000 and PowerPC are examples of processors that adopt Big Endian
byte ordering.
·
Little Endian. The least significant byte of data unit is
stored first in memory followed by the rest in ascending order of
significance. Examples of such processors are Intel x86 and Z80.
Note: Most modern computer processors agree on bit
ordering inside individual bytes. The library therefore has no provision for
manipulating bit ordering.
Back to the top
The library supports two modes of Modbus communication,
Modbus RTU and Modbus TCP. This can be set at compile time by setting
the value of the MODBUS_MODE macro.
Steps
a) Open file
MSPL_UserIf.h
b) Locate the definition
of macro MODBUS_MODE
c) To configure the
library to run in Modbus TCP mode, change the above macro’s value to MODBUS_TCP.
To set it to Modbus RTU mode, change the macro’s value to MODBUS_RTU.
The modified line should look like this:
#define
MODBUS_MODE MODBUS_TCP /* for Little Endian */
#define
MODBUS_MODE MODBUS_RTU /* for Big Endian */
d) Rebuild your project
and test.
Notes
·
Since this is a compile time setting, the mode cannot be changed
dynamically at run time.
·
Only one Modbus mode can be enabled at a time.
Back to the top
A communication channel has to be set up between physical
device and the Modbus library in order to receive Modbus request packets and
transmit response packets.
The Modbus standard provides allows users to choose their
own communication channel. Modbus compliant software is therefore unaware of
the characteristics of particular communication channels.
Therefore the library provides a set of unimplemented (i.e.
empty) hook functions that can be glued to the real interface functions of your
communication channel.
The hook functions cover the four communication operations.
|
S.No.
|
Channel Operation
|
Hook Function
|
Porting Notes
|
|
1
|
Open Port
|
MSPL_OpenPort
|
·
Use this function to open and configure communication channel
·
User application must call this function once for every channel
supported by the device
·
A unique channel identification number is passed as an argument
to this function.
·
Device driver API usually returns a path identifier or handle
to the channel being opened. This is required in subsequent operations:
read, write and close. Please ensure that your program stores this
identifier. See Win32 port implementation as an example.
|
|
2
|
Read from channel
|
MSPL_ReadPort
|
·
Library calls this function to read data from communication
channel
·
Function typically calls device driver’s “Read” API
·
A unique channel number is passed as an argument to identify
the channel.
·
Caution: Blocking calls to device driver API’s in this
function will block execution of MSPL-C as well as the application code that
is calling the library.
|
|
3.
|
Write to channel
|
MSPL_WritePort
|
·
Library calls this function to transmit data on communication
channel
·
Function typically calls device driver’s “Write” API
·
A unique channel number is passed as an argument to identify
the channel.
·
Caution: Blocking calls to device driver API’s in this
function will block execution of MSPL-C as well as the application code that
is calling the library.
|
|
4.
|
Close Port
|
MSPL_ClosePort
|
·
Use this function to close communication channel
·
User application calls this function when no Modbus
communication is required
·
A unique channel number is passed as an argument to identify
the channel.
|
Back to the top
MSPL-C supports simultaneous Modbus communication on
multiple channels.
This is achieved by dedicating a set of all global variables
to each communication channel.
Each channel now operates upon its own private dataset. In
effect the library can be used to create virtual Modbus devices.
The macro MAX_NETWORKS is used to set the maximum number of
channels required in the implementation.
Set this at compile time because the library uses static
memory allocation.
Back to the top
A Modbus TCP slave application is listens for connection
requests on the Modbus port no. and accepts multiple connections. This requires
a dedicated thread or task to listen for connection requests and accept them while
another set of dedicated threads and tasks handle further communication with
connected masters.
In MSPL-C, each connected socket is considered as a channel
of communication. There are three approaches you can take to support for
multiple Modbus TCP connections.
i.
A dedicated thread for listening to connection requests and accepting
them. Another set of threads to do further communication with connected clients
(i.e. one thread per connected client). The connection handling thread can
block waiting for new connection requests in this case.
ii. A
dedicated thread for listening to connection requests and accepting them.
Another thread (i.e. just one thread) to do further communication with
connected clients. In this case too, the connection handling thread can block
waiting for new connection requests.
iii. On
platforms that do not have a facility for multitasking, a single thread (i.e.
the main thread) will have to do the task of both listening for new connection
requests as well as handling communication with connected clients. Obviously,
the connection handling code cannot block waiting for new connection requests.
Instead such code should only query the underlying TCP/IP stack to enquire if a
new connection request has come in. If yes, it must be accepted and execution
must continue to the code that handles further Modbus communication with the
connected clients.
The Win32 port of MSPL-C demonstrates how to support
multiple Modbus TCP connections simultaneously.
Back to the top
The library handles the task of framing and de-framing
Modbus messages. The data within the messages are supplied by respective
application programs. The library encapsulates this data as per Modbus framing
rules and transmits it to the recipient.
Using the functions Read Coil and Write Coil to illustrate.
·
Read Coil: In response to the Read Coil command, the application
program running on the slave will supply data to the library. The library will
frame the data in accordance to Modbus framing rules and send it to the master,
completing the transaction.
·
Write Coil: The application running on the master supplies the
data to the library. The library encapsulates the data in the right frames and
forwards the framed message to the slave program, which executes the command.
Two functions in the MSPL_UserIf.c file facilitate the
interface between the library and your application and database.
·
MSPL_ReadUserData: Called by MSPL-C when it receives a “read”
type of Modbus request.
·
MSPL_WriteUserData: Called by MSPL-C when it receives a “write”
type of Modbus request.
User
is responsible for implementing these interface functions.
These two functions present a well defined interface that is
fully documented in this manual. The library supplied to you contains dummy
implementations of these functions with no code within.
Please refer to sample Win32 port for a complete reference.
Back to the top
A simulated database forms part of the library supplied. It
has a few variables of all the data types supported by the library.
Use this database as a first step to get the library working
on your platform. This exercise will assist in integrating the library with
the application’s database.
The database is created at the beginning of the
MSPL_UserIf.c file and contains the following data elements:
|
S.No.
|
Data Element
|
Associated Modbus Data Type
|
Number of Arrays
|
Memory Address
|
|
1
|
CSPL_U8 (single byte)
|
Coils, Discrete Inputs
|
2
|
0000 to 0015 (16 items)
|
|
2
|
CSPL_U16 (two byte)
|
Holding and Input Registers
|
2
|
0000 to 0010 (10 items)
|
|
3
|
Demonstrate mapping register to long integer
|
Float
|
1
|
0020 to 0029 (5 floats using 10 registers)
|
|
4
|
Demonstrate mapping register to long integer
|
Long Integer – 4 bytes
|
1
|
0040 to 0049 (5 long integers using 10 registers)
|
|
5
|
Demonstrate mapping register to string
|
Strings
|
1
|
0060 to 0063 (8 characters that can hold a ‘C’ string of
max length 7 using 4 registers)
|
The interface functions in the MSPL_UserIf.c file operate
upon this simulated database.
After testing with this database, you may replace it with
your own. Modify the interface functions to operate on your database.
Back to the top
MSPL-C provides you an extension to the Modbus
specifications by supplying a set of functions in file CSPL_Utils.c that
map the low level Modbus types (bits and words) to high level ‘C’ data types
(floats, integers and strings) with due consideration to the ENDIAN format of
your platform.
There are two categories of functions:
- Functions
that convert an array of raw data bytes as received via Modbus to an array of
higher level ‘C’ data type. They are usually called in MSPL_WriteUserData to
interpret the raw Modbus data as per the corresponding higher level
‘C’ datatype of the user database.
- Functions
that convert an array of some higher level ‘C’ data type into an array of raw
data bytes that can be transmitted via Modbus. They are usually called in MSPL_ReadUserData
to provide the library with user data in a Modbus compliant format.
Following is a brief description of each function:
|
Function name
|
Description
|
|
CSPL_PackBits
|
This function bit-packs a destination buffer with
bit status information provided in a source buffer. The source buffer is
expected to contain bit status (i.e a value of 0 or 1) in one byte per bit.
This data is bit-packed as 8-bits per byte in the destination buffer. For
e.g. if the input buffer is of this type:
CSPL_U8 srcBuffer[] = {0,1,1,0,1,1,0,0}
then the destination buffer’s first element will be stuffed
with the following value – 0x6C;
|
|
CSPL_UnPackBits
|
This function extracts bit status information from the
source buffer by unpacking the bits and copies it to the destination buffer.
The source buffer is expected to have bit packed data with one byte holding
the status of 8 bits. For e.g. if the if the input buffer is of this type:
CSPL_U8 srcBuffer[]={0xF1, 0xAB}
then this function will unpack this data to create the
following in the destination buffer
CSPL_U8 dstBuffer[]={1,1,1,1, 0,0,0,1,
1,0,1,0, 1,0,1,1}
|
|
CSPL_16BitIntsToBuffer
|
This function will copy data from a short integer array
(i.e. two byte integer) to an array of single byte values.
|
|
CSPL_32BitIntsToBuffer
|
This function is similar to CSPL_16BitIntsToBuffer
with the difference that it operates on 4-byte integer array.
|
|
CSPL_FloatsToBuffer
|
This function is similar to CSPL_16BitIntsToBuffer
with the difference that it operates on a floating point array. Each floating
point value is represented by four bytes in the destination buffer.
|
|
CSPL_StringToBuffer
|
This function copies a ‘C’ string into an array of bytes
including the terminating NULL character. It can be used send a character
string from the user database to a Modbus master.
|
|
CSPL_BufferTo16BitInts
|
This function performs the reverse task as the CSPL_16BitIntsToBuffer
function by mapping an array of bytes to a short integer array.
|
|
CSPL_BufferTo32BitInts
|
This function performs the reverse task as the CSPL_32BitIntsToBuffer
function by mapping an array of bytes to a long integer (4-byte) array.
|
|
CSPL_BufferToFloats
|
This function performs the reverse task as the CSPL_FloatsToBuffer
function by mapping an array of bytes to a floating point array
|
|
CSPL_BufferToString
|
This function performs the reverse task as the CSPL_StringToBuffer
function by mapping an array of bytes to a ‘C’ string.
|
Back to the top
MSPL-C has embedded debugging code to printout out useful
information to enable users to analyse, debug and diagnose the function of the
library. Such code can be enabled only during initial development and disabled
later to save code space as well as to decrease the CPU utilisation of the
library.
The type of debugging statements output by the library also
controlled at four levels as discussed in section 2.6.1
All diagnostics settings are done using ‘C’ macros making
them configurable only at compile time and not at run time. So configuring
diagnostics can be done with the following steps:
Step 1.
Select debugger level.
Step 2.
Include or exclude support for formatted I/O
Step 3.
Implement the debug “sink”
Back to the top
Enabling the debugger and setting the debug level is done by
defining a value for the DEBUG_LEVEL macro. This macro is defined in MSPL_UserIf.h
e.g.
#define DEBUG_LEVEL DEBUG_ERROR
This macro can be assigned one of the following values:
|
Macro Value
|
Description
|
|
DEBUG_NONE
|
This value disables the debugger. No debugging statements
are output from the library. This is the value you will use once your
application has been fully tested and ready to be released.
|
|
DEBUG_ERROR
|
This value causes the debugger to output statements when
any error occurs in the library. In a well tested application there should be
very few occurrences of “error debugger statements”. In a way, it’s a good
idea to set the debugger to this level during the initial period after a
release is done in order to capture errors that might occur post-release. An
example of an error condition is when the library finds that the Modbus
packet that has arrived is larger than the buffer size configured. In this
case the library outputs this message:
“Error: MSPL_ReadMbPdu:
Buffer too small to read PDU”
|
|
DEBUG_WARNING
|
This value causes the debugger to output relevant messages
when errors occur or when conditions occur that could potentially lead to
errors. An example of a warning is when the library receives a Modbus request
with the function code set to an unsupported value. In this case the library
outputs this message:
“Warning: Unsupported
function code, sending exception response”
|
|
DEBUG_INFORMATION
|
This value causes the debugger to output routine
information that indicates the overall status of the library and also shows
the flow of execution, in addition to error and warning messages. This is the
setting you will use in diagnosing any errors reported in the application. For
instance when the library receives a Modbus read request for Coils, it
outputs the following informational message:
“==> FC=0x01 (Read Coils)
“
|
|
DEBUG_VERBOSE
|
This value causes the debugger to output messages that can
be used for deep debugging. An example of such a message is when the library
outputs the value of each byte of the Modbus packet received by it as well as
that of the response. This setting is useful in diagnosing difficult problems
but at the same time generates an overwhelming amount of messages that can
get you lost.
|
Back to the top
If a function like sprintf
that implements formatted I/O is supported on the platform, the library can
make use of it to create more meaningful debugging messages. For instance if a
Modbus request with an unsupported function code is received, the debug message
will be formatted to contain the unsupported function code to make it easier to
debug the problem.
Support for formatted I/O can be
configured by setting the macro STDIO_SUPPORTED to a value of ‘1’ and
providing the name of the function to be used in the macro FORMATTED_STRING_PRINT.
Both these macros are defined in MSPL_UserIf.h.
#define STDIO_SUPPORTED
1 // Enable formatted I/O support
#define FORMATTED_STRING_PRINT
sprintf
Back to the top
The debugging messages output by
the library have to be finally output to a physical device like a display, a
printer or a serial terminal etc. This output device is referred to as the debug
sink. To provide the flexibility of choosing the debug sink to the user,
the library outputs its messages to a function called MSPL_DebugPrint.
This function is defined in MSPL_UserIf.c but is left unimplemented
(i.e. an empty function). Users should implement this function and sink the
debug message passed as an argument to an appropriate device.
The format of this function is as below:
void MSPL_DebugPrint(
CSPL_U8 networkNo, CSPL_U8 eventType,
char* debugMessage)
Parameters:
i. networkNo (IN): The network who Modbus
instance generated this debug print. This paramter enables redirecting of debug
prints from different networks to different sinks so that they do not all get
jumbled.
ii. eventType (IN): Indicates the debug level at
which this debug print was made. Possible values are one of: DEBUG_VERBOSE,
DEBUG_INFORMATION, DEBUG_WARNING and DEBUG_ERROR. A possible use of this
information is to print debug messages of different levels in different
colours.
iii. debugMessage (IN): A null-terminated ‘C’
string containing the debug message.
Shown below is a very simple
implementation of this hook function that adds a time stamp to the debugger
message and prints it to the standard output device.
void MSPL_DebugPrint(CSPL_U8 networkNo, CSPL_U8
eventType, char* debugMessage)
{
/* Add a time stamp to the debugger
message & print it to the
standard output
*/
SYSTEMTIME st;
GetLocalTime(&st);
printf("%d:%d:%d.%03d
- %s", st.wHour, st.wMinute, st.wSecond,
st.wMilliseconds, debugMessage);
}
Back to the top
Design
constrains change from one platform to another. While someone is constrained
for Data Memory (RAM) space, someone else is short of Code (Program) Memory
(ROM/Flash) while yet another is short of both. In order to accommodate MSPL
within the design constraints of most users, we have provided mechanisms to
save RAM, ROM or both. The following sub sections describe the steps involved
in using each of these techniques.
Back to the top
The library uses memory buffers
to store incoming Modbus packets before decoding them and to store response
packets before transmitting them. The sizes of these two buffers can be
controlled by limiting the maximum number of Modbus data items (i.e. coils, registers
etc.) that a master can request in one Modbus transaction. For instance if a
Modbus Master sends a read request for 100 registers in one packet, the
resulting response packet size will be greater than 200 bytes in comparison to
a read request for just 10 registers. You can configure the library to
entertain requests that can fit into a specific buffer size by defining the
following macros:
|
Macro Name
|
Location
|
Remarks
|
|
RX_BUFFER_SIZE
|
MSPL_UserIf.h
|
Limits the size of incoming packets. If the incoming
request packet size cannot be accommodated in this buffer size, the library
outputs an “Error” debugger message, discards the received packet and sends
no response to the master.
|
|
TX_BUFFER_SIZE
|
MSPL_UserIf.h
|
Limits the size of outgoing packets.
Note: No check is
made by the library to verify if a Modbus request results in a response
packet whose size is larger than this size.
|
Back to the top
2.7.1.1
Modbus Block Size Macros
Modbus block size is the number
of data items that a master zor operate upon in one Modbus transaction.
The size of a Modbus packet is
limited to 256 bytes for Modbus RTU and 260 bytes for Modbus TCP. This in
effect itself limits the number of items that can be operated upon in one
transaction as below:
|
Transaction
|
Max permissible block size
|
|
Read Coils, Read Discrete Inputs
|
2000 coils and Discrete Inputs respectively
|
|
Read Holding Registers, Read Input Registers
|
125 registers
|
|
Write Multiple Coils
|
1968 coils
|
|
Write Multiple Registers
|
123 registers
|
However, in order to receive and
service Modbus transactions that stretch up to the above max permissible
limits, a device needs a transmit and a receive buffer of 256 bytes (260 in
case of Modbus TCP). This may not be available or necessary in small devices
employing low end microcontrollers.
MSPL provides a way of using a
lower buffer sizes and a set of macros which can be used to filter out Modbus
transactions that exceed a set limit for block size. They are:
·
RD_BLK_SIZE_BITINFO
·
WR_BLK_SIZE_BITINFO
·
RD_BLK_SIZE_REGINFO
·
WR_BLK_SIZE_REGINFO
These macros must be set along
with RX_BUFFER_SIZE and TX_BUFFER_SIZE to optimize the use of memory.
Back to the top
The code size occupied by the
library can be minimized by including only the Modbus functions required in
your application and excluding others. For instance, if your device has only
digital inputs, there is no use of including support for Modbus function Read
Holding Register. The library provides a set of macros using which you can
selectively include or exclude Modbus functions.
Back to the top
2.7.2.1
How to use the Modbus function support macros
To include support for a Modbus function, set the macro to
‘1’, else set it to ‘0’.
Example:
#define
INCLUDE_READ_COILS 1 // Adds code to support Read
Coils function
#define
INCLUDE_READ_COILS 0 // Excludes code that implements
Read Coils
// function
Back to the top
2.7.2.2
How does the library respond to an unsupported function request
When the library receives a request for an unsupported
Modbus function it responds with Modbus Exception code 0x01 (ILLEGAL FUNCTION).
Back to the top
2.7.2.3
List of supported macros
|
Macro Name
|
Modbus Function Affected
|
|
INCLUDE_READ_COILS
|
Read Coils (Function Code 0x01)
|
|
INCLUDE_READ_DISCRETE_IP
|
Read Discrete Inputs (Function Code 0x02)
|
|
INCLUDE_READ_INPUT_REGS
|
Read Input Registers (Function Code 0x04)
|
|
INCLUDE_READ_HOLDING_REGS
|
Read Holding Registers (Function Code 0x03)
|
|
INCLUDE_WRITE_COILS
|
Write Multiple Coils (Function Code 0x0F)
|
|
INCLUDE_WRITE_REGISTERS
|
Write Multiple registers (Function Code 0x10)
|
Back to the top
The library maintains counters
for total Modbus messages received by it, total messages responded by it, total
errors encountered and so on. This functionality is optional, not mandatory, as
per the Modbus standard. So you may exclude this functionality by setting macro
INCLUDE_MSG_CTRS to zero.
#define
INCLUDE_MSG_CTRS 0 // Exclude message counters
related code
Back to the top
The amount of Code Memory
(sometimes called Program Memory) used by the library can be reduced
using two technics.
Method 1: Move CRC
tables into Data Memory (RAM)
Steps
a) Open
file MSPL_UserIf.h
b) Locate
the definition of macro CRC_TABLE_LOCATION
c) Change
its value to IN_RAM. The modified line should look like this:
#define CRC_TABLE_LOCATION IN_RAM
d) Rebuild
your project. You should see a reduction in code size by approximately 512
bytes and a corresponding increase in RAM usage.
Description
Two tables of 256 constant values
are used in computing CRC bytes. The location of these tables is
configurable. The above steps cause the tables to be stored in data memory.
This saves code memory at the expense of data memory by moving the tables into
RAM. Since RAM is faster than ROM access, this method may also improve the
efficiency of code execution.
Method 2: Eliminate CRC table storage by computing
table contents dynamically
Steps
a) Open
file MSPL_UserIf.h
b) Locate
the definition of macro CRC_TABLE_LOCATION
c) Change
its value to CREATE_DYNAMIC. The modified line should look like this:
#define CRC_TABLE_LOCATION CREATE_DYNAMIC
d) Rebuild
your project. You should see a reduction in code size by approximately 512
bytes without a proportional increase in RAM usage.
Description
This setting eliminates the two
CRC tables altogether by computing the values of this table dynamically as and
when required. This saves both code memory as well as data memory. However,
since the CRC table contents are computed twice (once for verifying the CRC of
received request ADU and again for computing the CRC for the response ADU) for
every Modbus transaction, this method considerable increases the load on the
CPU. This may lead to slower response times from the library.
Back to the top
2.7.5 Reduce
Data Memory (RAM) size by configuring CRC macros
The amount of Data Memory
(sometimes called as RAM) used by the library can be reduced using two
techniques.
Method 1: Move CRC
tables into Code Memory (ROM)
Steps
a) Open
file MSPL_UserIf.h
b) Locate
the definition of macro CRC_TABLE_LOCATION
c) Change
its value to IN_ROM. The modified line should look like this:
#define CRC_TABLE_LOCATION IN_ROM
d) Rebuild
your project. You should see a reduction in RAM usage but an increase in the
code size.
Description
Two tables of 256 constant values
are used in computing CRC bytes. The location of these tables is
configurable. The above steps cause the tables to be stored in code memory.
This saves data memory (RAM) at the expense of code memory (ROM) by moving the
tables into ROM.
Method 2: Eliminate
CRC table storage by computing table contents dynamically
See here
Back to the top
If you have reached here then you
have:
§
Created a project in your IDE and added the MSPL files to it
§
Implemented the hook functions to glue the library to your
platform’s physical interface
§
Implemented the hook functions to glue the library to your
application’s database or are using the simulated database
§
Configured the debugger
§
Defined appropriate values for various open macros to set the
Endian style, optimise the memory utilisation etc.
Use the facilities of the IDE now
to compile and build the project and download it to your target. You can test
this port with the bundled Modbus Protocol Tester application.
Back to the top
The Modbus Protocol Tester or MPT
in short is a simple Windows Modbus Master application that enables a user to
send Modbus requests to a slave device and decode the response. It can be
configured to poll specified data points in the slave device at a periodic
interval and generate a log if any error occurs. It can display raw Modbus
packets as well as the data extracted from a Modbus packet. The data can be
shown as raw Modbus data (bits and words) or as interpreted data (integers,
floats and so on). It is an excellent light-weight test tool to validate a
Modbus device’s compliance to the supported function codes and also perform
stress tests on it by bombarding it with Modbus requests.
Back to the top
The setup file for the Modbus
Protocol Tester is in the “..\MPT” folder of MSPL-C package. Run setup.exe from
this folder and follow the onscreen instructions to complete the installation.
Back to the top
Modbus Protocol Tester online user’s manual can be found at http://www.colwaysolutions.com/topic-based-user-manual.html
Back to the top
Once you have ported the library
to your platform, it is time to make calls into its API’s. The following table
shows a list of API’s that may be called by the user’s application:
|
API
|
When to call
|
Mandatory?
|
Remarks
|
|
MSPL_RunModbus
|
Periodically for every channel, as soon as some bytes have
arrived into the channel.
|
Yes
|
·
This is the main entry point into the library, also called as
the trigger function.
·
This function triggers the stack which checks if data has
arrived on the specified channel and processes it.
·
This function must be called after the communication channel’s
device driver is queried to see if some data has been received in its buffer.
|
|
MSPL_OpenPort
|
On program start up, once for every communication channel
to be opened and initialised.
|
No (optional)
|
·
The user is free to perform channel initialisation outside of
the library in which case this function need not be implemented and/or
called.
|
|
MSPL_ClosePort
|
Once per channel when Modbus communication is no longer
required on that channel.
|
No (optional)
|
·
In applications where Modbus communication is expected to be active
until the device is switched OFF, this function need not be called at all.
·
As for MSPL_OpenPort, user may choose to implement
channel de-initialisation code outside the library in which case this
function need not be implemented or called.
|
|
MSPL_GetMessageCounters
|
When the value of statistical counters maintained by the
stack are required.
|
No (optional)
|
·
Details of the counters can be found in the function reference
section for MSPL_GetMessageCounters()
|
Back to the top
Diagram below shows a flowchart
of invocation of the MSPL_OpenPort function and MSPL_RunModbus
function.
Back to the top
The MSPL-C Configurator is a
Windows software that you can use to graphically set values for macros of the
library. This tool directly modifies the MSPL_UserIf.c file in the same manner
as you would change values for macros manually.

Back to the top
Figure above shows a snapshot of
the MSPL-C Configurator User Interface. The following is the procedure to use
this utility:
Step
1. Click “Browse”
to navigate to the folder containing the MSPL-C source files and select the
file MSPL_UserIf.c (only this file is required to begin using the
utility). On choosing the file, all fields in the UI will get populated with
the values of macros read from this file. The pathname of the folder selected
appears in the text box labelled “MSPL-C Location”.
Step
2. Modify values
of any of the configuration parameter that you desire.
Step
3. In the process
if you intend to discard any changes you have done and reset the UI to the
values in MSPL_UserIf.c, press “Reload”
Step
4. Once you are
satisfied with the changes made by you save them back to the MSPL_UserIf.c file
by pressing “Save Changes”. This step will modify this file by changing the
values of the macros contained in it. So ensure that the file is writable.
Back to the top
Each control on the configurator
window controls the value of a macro. Table below provides the full list of
controls and the macros that they affect. Descriptions of the macros themselves
are covered in various sub-sections of the section “How to port MSPL-C to your
platform”.
|
Control Group
|
Control Name
|
Macro affected
|
Value set for macro
|
|
CRC Table Location Settings
|
CRC Tables in ROM
|
CRC_TABLE_LOCATION
|
IN_ROM
|
|
CRC Tables in RAM
|
CRC_TABLE_LOCATION
|
IN_RAM
|
|
Dynamic CRC Tables
|
CRC_TABLE_LOCATION
|
CREATE_DYNAMIC
|
|
Enable Function Groups
|
Read Coils
|
INCLUDE_READ_COILS
|
1 if checked, else 0
|
|
Read Discrete Inputs
|
INCLUDE_READ_DISCRETE_IP
|
1 if checked, else 0
|
|
Read Holding Registers
|
INCLUDE_READ_HOLDING_REGS
|
1 if checked, else 0
|
|
Read Input Registers
|
INCLUDE_READ_INPUT_RaEGS
|
1 if checked, else 0
|
|
Write Coils
|
INCLUDE_WRITE_COILS
|
1 if checked, else 0
|
|
Write Holding Registers
|
INCLUDE_WRITE_REGISTERS
|
1 if checked, else 0
|
|
Debugger Settings
|
Enable Debugging
|
DEBUG_LEVEL
|
DEBUG_NONE if unchecked else one of the values below
|
|
Verbose
|
DEBUG_LEVEL
|
DEBUG_VERBOSE
|
|
Information
|
DEBUG_LEVEL
|
DEBUG_INFORMATION
|
|
Warning
|
DEBUG_LEVEL
|
DEBUG_WARNING
|
|
Error
|
DEBUG_LEVEL
|
DEBUG_ERROR
|
|
STDIO Supported
|
STDIO_SUPPORTED
|
1 if checked, else 0
|
|
Modbus Mode
|
Modbus TCP
|
MODBUS_MODE
|
MODBUS_TCP
|
|
Modbus RTU
|
MODBUS_MODE
|
MODBUS_RTU
|
|
Endian Style
|
Big Endian
|
ENDIAN_STYLE
|
BIG_ENDIAN
|
|
Little Endian
|
ENDIAN_STYLE
|
LITTLE_ENDIAN
|
|
Modbus Block Size Limits
|
Read Bit Status
|
RD_BLK_SIZE_BITINFO
|
Value entered in text box. Permitted range: 8-2000.
|
|
Read Register Value
|
RD_BLK_SIZE_REGINFO
|
Value entered in text box. Permitted range: 1-125.
|
|
Write Bit Status
|
WR_BLK_SIZE_BITINFO
|
Value entered in text box. Permitted range: 8-1968.
|
|
Write Register Value
|
WR_BLK_SIZE_REGINFO
|
Value entered in text box. Permitted range: 1-123.
|
|
Variable Location Modifiers
|
Const variables in ROM
|
CRC_TABLE_LOC_MODIFIER
|
Text entered in text box
|
|
Variables in external RAM
|
DATA_IN_XRAM
|
Text entered in text box
|
|
Network Settings
|
No. of Networks
|
MAX_NETWORKS
|
Value entered in text box
|
Back to the top
Two most common types of
multitasking environments in use are the process based RTOS and a task
based RTOS. They differ in the following characteristics:
|
Process based RTOS
|
Task based RTOS
|
|
Each process has a dedicated global memory space.
|
All tasks share a common global memory space.
|
|
A global variable with the same name can exist between two
processes.
|
A global variable created in one file is visible to all
tasks. So global variables should have unique names.
|
|
Functions of a library used by a process need not be re-entrant
or thread-safe since a call to it by multiple processes will always
act only on the global data of the calling process, if any.
|
Since function calls by any of the tasks act on shared
global data, functions of a library used by multiple tasks simultaneously
need be re-entrant or thread-safe.
|
|
Examples: WinCE, OS9
|
Examples: VxWorks, uC/OS II, MQX, embOS
|
MSPL-C has its set of global
variables. So these differences have an impact on how MSPL-C can be used in
these multitasking environments. Consider the following guidelines when using
MSPL-C in an RTOS:
a.
In a process based RTOS, fork multiple processes to support many Modbus
TCP connections with each process handling one connection. However, set MAX_NETWORKS
macro in MSPL_UserIf.h to one (1) only. Each process behaves as if it is the
only Modbus device in the system.
b.
In a task based RTOS, fork multiple tasks to support many Modbus TCP
connections. In this case the MAX_NETWORKS macro should be set to the maximum
number of tasks that will simultaneously use the library.
Back to the top
These data types are defined in CSPL_MbDefs.h
|
MSPL-C Data type
|
Native definition
|
|
CSPL_U8
|
unsigned char
|
|
CSPL_U16
|
unsigned short int
|
|
CSPL_U32
|
unsigned int
|
|
CSPL_I8
|
char
|
|
CSPL_I16
|
short int
|
|
CSPL_I32
|
int
|
|
CSPL_BOOL
|
typedef enum
_CSPL_BOOL
{
CSPL_FALSE,
CSPL_TRUE
}CSPL_BOOL;
|
Back to the top
|
Function name
|
MSPL_UserInit
|
|
Description
|
This function is called by MSPL_Init() in order to allow
any user/application specific initialisation to be done. This is a good
place, for instance, to create/link to any synchronisation semaphores,
initialise your own application globals or print some start up messages.
|
|
Returns
|
CSPL_BOOL. A status code. This code is passed back
by MSPL_Init() to its caller who can take appropriate action on failure.
|
|
Possible return values
|
CSPL_TRUE – All user/application specific initialisation
went OK.
CSPL_FALSE – Something went wrong during user de-initialisation.
|
|
Arguments
|
None
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ UserDeInit
|
|
Description
|
This function is called by the MSPL_DeInit() function of
the library in order to allow any user/application specific
de-initialisation/cleanup to be done. This is a good place, for instance, to
close handles to any operating system objects that the application code might
be using.
|
|
Returns
|
CSPL_BOOL. A status code. This code is passed back
by MSPL_DeInit() to its caller who can take appropriate action on failure.
|
|
Possible return values
|
CSPL_TRUE – All user/application specific de-initialisation
went OK.
CSPL_FALSE – Something went wrong during user
de-initialisation.
|
|
Arguments
|
None
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ OpenPort
|
|
Description
|
This function should open communication port and
initialise it so as to get it ready for receiving Modbus packets and sending
responses.
This is the place to set all communication parameters like
baud rate, parity, port timeouts etc. This function is not internally called
by the library but must be called by the user during start up of his
application, once for each port that will support Modbus communication.
|
|
Returns
|
CSPL_U8. A value indicating if the specified port
was opened and initialised successfully or not.
|
|
Possible return values
|
CSPL_TRUE – The specified port was opened and initialised
successfully.
CSPL_FALSE – The specified port could not be opened or
initialised.
|
|
Arguments
|
CSPL_U8 networkNo
|
A number identifying the “port” or channel used for Modbus
communication that is to be initialised.
|
|
Called by
|
User application
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ ClosePort
|
|
Description
|
The implementation of this function should close the
specified port and release all resources held by it. This function is not
called directly by the library. It must instead be called by the user of the
library when Modbus support on a communication port is no longer required.
|
|
Returns
|
CSPL_U8. A value indicating success or failure of
the function.
|
|
Possible return values
|
CSPL_TRUE – The port was closed successfully.
CSPL_FALSE – The port could not be closed successfully.
|
|
Arguments
|
CSPL_U8 networkNo
|
A number identifying the “port” or channel to be closed.
|
|
Called by
|
User application
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_CheckSlaveId
|
|
Description
|
This function is called by the library soon after it reads
the Slave ID field from a Modbus ADU in order to know if the Modbus packet is
intended for this device or not. The implementation of this function should
return a value indicating if the packet is to be processed further or not.
|
|
Returns
|
CSPL_BOOL. A value indicating if the slave ID
passed identifies this device or not.
|
|
Possible return values
|
CSPL_TRUE – Slave ID passed identifies this device and so
this Modbus ADU may be processed further.
CSPL_FALSE – Slave ID passed does not identify this
device.
|
|
Arguments
|
CSPL_U8 slaveID
|
The slave ID to be validated.
|
|
CSPL_U8 networkNo
|
The network on which this Modbus ADU was received. this
parameter may be ignored if the device presents itself on all the networks
with the same slave ID.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ ValidateAddresses
|
|
Description
|
This function is called by the library to check if the combination
of data address range and the function code in the Modbus PDU is valid for
this device.
|
|
Returns
|
CSPL_BOOL. A value indicating if the address range
is valid or not. If not, the library responds to this ADU with an ILLEGAL
DATA ADDRESS (0x02) Exception response.
|
|
Possible return values
|
CSPL_TRUE – The address range is valid.
CSPL_FALSE – The address range is not valid.
|
|
Arguments
|
CSPL_U8 slaveID
|
A single byte value containing the slave ID of the ADU for
which the data addresses are to be validated.
The slave ID is useful in cases where the library is being
used to implement a virtual multi slave device where validation of addresses
will be different for different slave ID’s. If the device behaviour is
independent of the slave ID to which a Modbus request is addressed to, then
this parameter may be ignored.
|
|
CSPL_U8 networkNo
|
The network on which this Modbus ADU was received. If the
device behaviour is independent of the network on which a Modbus request is
received, then this parameter may be ignored.
|
|
CSPL_U8 functionCode
|
A single byte value of the Modbus function code associated
with the data addresses to be validated.
|
|
CSPL_U16 startAddress
|
A two-byte value that is the first address in the range to
be validated.
|
|
CSPL_U16 noOfItems
|
A two-byte value that is the number of addresses starting
from startAddress that are to be validated.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ ReadUserData
|
|
Description
|
The library calls this function for all PDU’s that contain
a Modbus “read” service request and expects its implementation to copy the
relevant data from the user’s database to the buffer it passes as one of the
arguments. The buffer passed for holding the data must be filled in a
specific format as indicated below, the format itself being data type
specific. Helper functions are provided in file CSPL_Utils.c to assist the
user in easily filling this buffer in the correct format. The formats have
been chosen to keep the usage of memory to the minimum.
|
Type of data
|
Format in which data is to be stored in pBuffer
|
|
Bit Status
|
Bit stuffed as 8 status information in one byte
|
|
Registers
|
One register as two consecutive bytes in big endian
format
|
|
|
Returns
|
CSPL_U8. A value indicating if the read request was
processed successfully or not.
|
|
Possible return values
|
= 0 – if the service request executed successfully
> 0 – if the service request failed in which case the
library sends a SLAVE DEVICE FAILURE Exception response (code 0x04) to the
Modbus master.
|
|
Arguments
|
CSPL_U8 slaveID
|
A single byte value containing the slave ID of the ADU for
which the data addresses are to be validated.
The slave ID is useful in cases where the library is being
used to implement a virtual multi slave device where validation of addresses
will be different for different slave ID’s. If the device behaviour is
independent of the slave ID to which a Modbus request is addressed to, then
this parameter may be ignored.
|
|
CSPL_U8 networkNo
|
The network on which this Modbus ADU was received. If the
device behaviour is independent of the network on which a Modbus request is
received, then this parameter may be ignored.
|
|
CSPL_U8 functionCode
|
A single byte value of the Modbus function code that defines
the Modbus service request. This parameter can be checked to see what kind of
data (coil, discrete input, register etc.) is being requested for.
|
|
CSPL_U16 startAddress
|
A two-byte value that is the first address in the range of
data being requested for.
|
|
CSPL_U16 noOfItems
|
A two-byte value that is the number of data items starting
from startAddress that are being requested for.
|
|
CSPL_U8 *pBuffer
|
Pointer to an array of bytes into which the requested data
must be copied into in the correct format.
Appropriate helper functions may be used in stuffing the
data in the right format into this buffer.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ WriteUserData
|
|
Description
|
This function is used transfer data from a Modbus PDU to
the user’s database. The library calls this function for all PDU’s that
contain a Modbus “write” service request and expects its implementation to
copy the relevant data from the buffer it passes as one of the arguments to
the user’s database. The buffer passed contains the PDU data in a specific
format as described below. Helper functions are provided in file CSPL_Utils.c
to assist the user in easily decoding and copying data in this buffer to his application’s
database. The formats have been chosen to keep the usage of memory to the
minimum.
|
Type of data
|
Format in which data is stored in pBuffer
|
|
Bit Status
|
Bit stuffed as 8 status information in one byte
|
|
Registers
|
One register as two consecutive bytes in big endian
format
|
|
|
Returns
|
CSPL_U8. A value indicating if the write request
was processed successfully or not.
|
|
Possible return values
|
= 0 – if the service request executed successfully
> 0 – if the service request failed in which case the
library sends a SLAVE DEVICE FAILURE Exception response (code 0x04) to the
Modbus master.
|
|
Arguments
|
CSPL_U8 slaveID
|
A single byte value containing the slave ID of the ADU for
which the data addresses are to be validated.
The slave ID is useful in cases where the library is being
used to implement a virtual multi slave device where validation of addresses
will be different for different slave ID’s. If the device behaviour is
independent of the slave ID to which a Modbus request is addressed to, then
this parameter may be ignored.
|
|
CSPL_U8 networkNo
|
The network on which this Modbus ADU was received. If the
device behaviour is independent of the network on which a Modbus request is
received, then this parameter may be ignored.
|
|
CSPL_U8 functionCode
|
A single byte value of the Modbus function code that
defines the Modbus service request. This parameter can be checked to see what
kind of data (coil, discrete input, register etc.) is present in the buffer and
which Modbus service is being used to write the data.
|
|
CSPL_U16 startAddress
|
A two-byte value that is the first address in the range of
data being written to.
|
|
CSPL_U16 noOfItems
|
A two-byte value indicating the number of data items
starting from startAddress that are being written to.
If functionCode is 0x05 or 0x06 then noOfItems
will be ‘1’.
|
|
CSPL_U8 *pBuffer
|
Pointer to an array of bytes containing the data. The
library fills this buffer with data from the received PDU.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ ReadPort
|
|
Description
|
This function is called by the library to read a Modbus
packet from a communication port.
|
|
Returns
|
CSPL_U8. A value indicating success or failure of
the function.
|
|
Possible return values
|
CSPL_TRUE - if the function is able to read at least one
byte from the port before a read timeout occurs. The actual number of bytes
read should be stored in pNoOfBytesRead.
CSPL_FALSE – if the function is unable to read any byte
from the port before a read timeout occurs or if it encounters an error in
reading the port. In this case an error code indicating the reason for
failure should be stored in pErrorCode argument.
|
|
Arguments
|
CSPL_U8 networkNo
|
A number identifying the “port” to be read.
|
|
CSPL_U16 noOfBytesToRead
|
The number of bytes to read on this port.
|
|
CSPL_U16 *pNoOfBytesRead
|
A pointer to the variable that receives the actual number
of bytes read.
|
|
CSPL_U8 *pBuffer
|
A pointer to the buffer that receives the data read from
the port.
|
|
CSPL_U8 *pErrorCode
|
A pointer to the variable that receives an error code in
case of failure of this function.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ WritePort
|
|
Description
|
This function is called by the library to write a Modbus
response packet to a communication port.
|
|
Returns
|
CSPL_U8. A value indicating success or failure of
the function.
|
|
Possible return values
|
CSPL_TRUE - if the function is able to write at least one
byte to the port before a write timeout occurs. The actual number of bytes
written should be stored in pNoOfBytesWritten.
CSPL_FALSE – if the function is unable to write any byte
to the port before a write timeout occurs or if it encounters an error in
writing to the port. In this case an error code indicating the reason for
failure should be stored in pErrorCode argument.
|
|
Arguments
|
CSPL_U8 networkNo
|
A number identifying the “port” to be read.
|
|
CSPL_U16 noOfBytesToWrite
|
The number of bytes to write to this port.
|
|
CSPL_U16 * pNoOfBytesWritten
|
A pointer to the variable that receives the actual number
of bytes written.
|
|
CSPL_U8 *pBuffer
|
A pointer to the buffer containing the data to be written
to the port.
|
|
CSPL_U8 *pErrorCode
|
A pointer to the variable that receives an error code in
case of failure of this function.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_ DebugPrint
|
|
Description
|
The library calls this function to output a debug message.
Users may implement this function to sink the debug message to an output
device of their choice (e.g. to a printer, to an LCD, to a file and so on.).
This function is called only when debugging is enabled by way of macro DEBUG_LEVEL.
|
|
Returns
|
None
|
|
Arguments
|
CSPL_U8 networkNo
|
The network on which a Modbus transaction was occurring
that caused this debug message. This argument enables redirecting of debug
prints from different networks to different sinks so that they do not all get
jumbled.
|
|
CSPL_U8 eventType
|
The debug level of this message. Possible values are:
·
DEBUG_VERBOSE
·
DEBUG_INFORMATION
·
DEBUG_WARNING
·
DEBUG_ERROR.
A possible use of this information is to print debug
messages of different levels in different colours.
|
|
CSPL_CHAR* debugMessage
|
A null-terminated ‘C’ string containing the debug message.
|
|
Called by
|
Library
|
|
User Implements?
|
Yes
|
Back to the top
|
Function name
|
MSPL_RunModbus
|
|
Description
|
This is the entry point function into the library which
must be run periodically to execute the Modbus stack. When called, it reads
the channel (passed as an argument) to check if any data has been received.
If so, it attempts to process the packet received as a Modbus frame and if
required sends out a response.
|
|
Returns
|
CSPL_U8. A status code as shown in section below
titled “Status codes returned by function MSPL_RunModbus”
|
|
Arguments
|
CSPL_U8 networkNo
|
The channel on which this function must look for a Modbus
packet. The library passes this parameter to every hook function that it
calls from MSPL_UserIf.h. Since this function processes one channel at a
time, it must be called once for every channel configured for Modbus in your
system.
|
|
Called by
|
User application
|
|
User Implements?
|
No
|
Back to the top
6.2.13 Status codes
returned by function MSPL_RunModbus
The following error codes may be returned by the main entry
point function MSPL_RunModbus. They are defined in CSPL_MbDefs.h
|
Error
|
Code
|
Remarks
|
|
MSPL_NO_ERROR
|
0x00
|
No error was encountered and the function executed
successfully
|
|
UNKNOWN_ERROR
|
0x01
|
An unknown error occurred reading / writing to port. This
indicates that the underlying device driver API for read/write returned an
unknown code when invoked.
|
|
INVALID_HANDLE
|
0x02
|
An invalid handle or path ID was used to read from / write
to the port.
|
|
INVALID_NETWORKNUM
|
0x03
|
An uninitialized network number was passed as a parameter.
Indicates that an attempt was made to use a channel that has not been
initialised with a call to MSPL_OpenPort().
|
|
READ_WRITE_FAIL
|
0x04
|
Device failure reading / writing to port. Indicates that
the underlying device driver API for read/write returned an error code.
|
|
READ_WRITE_TIMEOUT
|
0x05
|
Timeout occurred reading / writing bytes. Indicates that
the library called MSPL_ReadPort which returned with no data but a
timeout.
|
|
ID_MISMATCH
|
0x06
|
The slave ID found in the Modbus request does not match
this device. Indicates that the library encountered a message that was
directed to a different slave. In case of Modbus RTU, this could occur
frequently when using a shared bus like RS485 whereas in case of Modbus TCP,
this error code indicates a true errpr.
|
|
CRC_ERR
|
0x07
|
The message contained incorrect CRC Bytes. Indicates a
corrupt message. Modbus RTU only.
|
|
BUFFER_TOO_SMALL
|
0x08
|
The request message has more bytes than the available size
of buffer. Indicates that the master is trying to read or write too many
Modbus data units that the block sizes configured for the library.
|
|
PORT_CLOSED
|
0x09
|
The communication port was closed when trying to read or
write on it. This error commonly occurs when a TCP connection is closed just
when the library was trying to read from the channel.
|
|
INVALID_FC
|
0x0A
|
An invalid/unsupported function code was requested to be
serviced.
|
Back to the top
|
Function name
|
MSPL_GetMessageCounters
|
|
Description
|
This function provides the value of various message
counters maintained by the stack.
|
|
Returns
|
MSPL_MB_MSG_CTRS. A structure containing the
counters maintained by the stack. See section below titled “Structure MSPL_MB_MSG_CTRS” for
details of these counters.
|
|
Arguments
|
CSPL_U8 networkNo
|
The channel whose counters are being requested. The stack
maintains an exclusive set of counters for each channel.
|
|
Called by
|
User application
|
|
User Implements?
|
No
|
Back to the top
6.2.14.1 Structure MSPL_MB_MSG_CTRS
|
Member
|
Data Type
|
Description of the counter
|
|
busMsgCnt
|
CSPL_U32
|
Quantity of messages that the remote device has detected
on the communication channel since its last restart, clear counters operation
or power–up.
|
|
busCommErrCnt
|
CSPL_U32
|
Quantity of CRC errors encountered by the remote device on
this channel since its last restart, clear counters operation or power–up.
This member is present only in Modbus RTU mode.
|
|
busExcpErrCnt
|
CSPL_U32
|
Quantity of MODBUS exception responses returned by the
remote device since its last restart, clear counters operation or power–up.
|
|
slvMsgCnt
|
CSPL_U32
|
Quantity of messages addressed to the remote device, or
broadcast on this channel, that the remote device has processed since its
last restart, clear counters operation, or power–up.
|
Back to the top
|
Macro name
|
MODBUS_MODE
|
|
Description
|
Controls the Modbus framing type followed by the library.
|
|
Permitted Values
|
MODBUS_TCP
|
Sets framing type to Modbus TCP
|
|
MODBUS_RTU
|
Sets framing type to Modbus RTU
|
|
Remarks
|
·
Two framing types are supported by the library – Modbus RTU and
Modbus TCP.
|
Back to the top
|
Macro name
|
ENDIAN_STYLE
|
|
Description
|
Defines the Endian style of the processor running the
library.
|
|
Permitted Values
|
LITTLE_ENDIAN
|
Processor is of type Little Endian
|
|
BIG_ENDIAN
|
Processor is of type Big Endian
|
|
Remarks
|
·
Since Modbus is Big Endian, appropriate conversion logic is
required when the library is run on a Little Endian processor. The library
uses this macro to run such conversion logic conditionally wherever required.
|
Back to the top
|
Macro name
|
INCLUDE_READ_COILS
INCLUDE_READ_DISCRETE_IP
INCLUDE_READ_INPUT_REGS
INCLUDE_READ_HOLDING_REGS
INCLUDE_WRITE_COILS
INCLUDE_WRITE_REGISTERS
|
|
Description
|
Selectively includes or excludes support for a Modbus
function.
|
|
Permitted Values
|
1
|
Includes source code for the related Modbus
functions
|
|
0
|
Excludes source code for the related Modbus
functions
|
|
Remarks
|
·
Used to optimise library by excluding source code of
unsupported functions thus making the library smaller.
·
The macro names are self suggestive of the Modbus functions
that they affect.
|
Back to the top
|
Macro name
|
INCLUDE_MSG_CTRS
|
|
Description
|
Controls inclusion or exclusion of code related to
maintenance of message counters in the library.
|
|
Permitted Values
|
1
|
Includes source code for supporting message
counters
|
|
0
|
Excludes source code for supporting message
counters
|
|
Remarks
|
·
Used to compress the code size by excluding support for message
counters.
|
Back to the top
|
Macro name
|
RD_BLK_SIZE_BITINFO
|
|
Description
|
Fixes the maximum limit to the number of bit status
information (both coils and discrete inputs) that may be requested
by a Master in one Modbus transaction.
|
|
Permitted Values
|
8 to 2000
|
|
|
Remarks
|
·
A smaller block size limit will enable setting a smaller value
for macro TX_BUFFER_SIZE thus reducing the memory used by the library for
holding Modbus response packets.
·
If a Read Coils or Read Discrete Inputs request is received
with the number of items set to more than RD_BLK_SIZE_BITINFO, the library
responds with an ILLEGAL DATA ADDRESS (0x03) exception code.
|
Back to the top
|
Macro name
|
RD_BLK_SIZE_REGINFO
|
|
Description
|
Fixes the maximum limit to the number of register
values (both holding registers and input registers) that may be requested
by a Master in one Modbus transaction.
|
|
Permitted Values
|
1 to 125
|
|
|
Remarks
|
·
A smaller block size limit will enable setting a smaller value
for macro TX_BUFFER_SIZE thus reducing the memory used by the library for
holding Modbus response packets.
·
If a Read Holding Registers or Read Input Registers request is
received with the number of items set to more than RD_BLK_SIZE_REGINFO, the
library responds with an ILLEGAL DATA ADDRESS (0x03) exception code.
|
Back to the top
|
Macro name
|
WR_BLK_SIZE_BITINFO
|
|
Description
|
Fixes the maximum limit to the number of coils that
may be written to by a Master in one Modbus transaction.
|
|
Permitted Values
|
8 to 1968
|
|
|
Remarks
|
·
A smaller block size limit will enable setting a smaller value
for macro TX_BUFFER_SIZE thus reducing the memory used by the library for
holding Modbus request packets.
·
If a Write Multiple Coils request is received with the number
of items set to more than WR_BLK_SIZE_BITINFO, the library responds with an
ILLEGAL DATA ADDRESS (0x03) exception code.
|
Back to the top
|
Macro name
|
WR_BLK_SIZE_REGINFO
|
|
Description
|
Fixes the maximum limit to the number of holding
registers that may be written to by a Master in one Modbus
transaction. A smaller block size limit will enable setting a smaller value
for macro RX_BUFFER_SIZE thus reducing the memory used by the library for
holding Modbus request packets.
|
|
Permitted Values
|
1 to 123
|
|
|
Remarks
|
·
A smaller block size limit will enable setting a smaller value
for macro TX_BUFFER_SIZE thus reducing the memory used by the library for
holding Modbus request packets.
·
If a Write Multiple Registers request is received with the
number of items set to more than WR_BLK_SIZE_REGINFO, the library responds
with an ILLEGAL DATA ADDRESS (0x03) exception code.
|
Back to the top
|
Macro name
|
RX_BUFFER_SIZE
TX_BUFFER_SIZE
|
|
Description
|
These macros control the sizes of receive and transmit
buffers that the library allocates for receiving Modbus requests and sending responses.
|
|
Permitted Values
|
7 - 256
|
Modbus RTU
|
|
11 - 260
|
Modbus TCP
|
|
Remarks
|
·
RX_BUFFER_SIZE must be set large enough for the library to
support the block size limits specified by WR_BLK_SIZE_BITINFO and WR_BLK_SIZE_REGINFO.
·
TX_BUFFER_SIZE must be set large enough for the library to
support the block size limits specified by RD_BLK_SIZE_BITINFO and RD_BLK_SIZE_REGINFO.
·
The recommended way to set these macros is by using the MSPL configurator
which automatically calculates the values for the buffers based on the values
set for the block size limiting macros.
·
If these macros are manually set, ensure that the buffers are
large enough to hold the MBAP header (Modbus TCP only) or the Slave/Server
Address (Modbus RTU only), the Modbus PDU and the CRC bytes (Modbus RTU
only)
|
Back to the top
|
Macro name
|
STDIO_SUPPORTED
|
|
Description
|
Indicates to the library if the platform supports
formatted I/O or not.
|
|
Permitted Values
|
1
|
Formatted I/O supported
|
|
0
|
Formatted I/O not supported
|
|
Remarks
|
·
This macro is used by the library when creating debug messages.
·
If the value for this macro is 1, the library formats debug
messages with relevant numerical information by using sprint formatted
I/O function. If not, the debug messages are plain textual information only.
·
If this macro is set to 1, then the macro FORMATTED_STRING_PRINT
must also be set to the name of the function on your platform that
provides standard ‘C’ sprint function-like functionality. Relevant
header file may have to be included within MSPL_UserIf.h file to
support your formatted I/O function.
|
Back to the top
|
Macro name
|
FORMATTED_STRING_PRINT
|
|
Description
|
This macro must be set to the name of the ‘C’ function
that can do a formatted print into a ‘C’ string. Usually the name of such a
function is itself sprint.
|
|
Permitted Values
|
Name of formatted string print function.
|
|
Remarks
|
·
This macro is used only when STDIO_SUPPORTED is set to 1.
·
See remarks under STDIO_SUPPORTED for more information.
|
Back to the top
|
Macro name
|
DEBUG_LEVEL
|
|
Description
|
This macro is used to enable or disable output of
debugging messages by the library and to set the type of instances for which
a debug message is generated.
|
|
Permitted Values
|
DEBUG_NONE
|
Debug message generation is disabled.
|
|
DEBUG_ERROR
|
Debug messages are generated only when error conditions
occur in the library execution.
|
|
DEBUG_WARNING
|
Debug messages are generated only when error conditions or
such other conditions occur in the library execution that could lead to
potential error conditions.
|
|
DEBUG_INFORMATION
|
In addition to generating debug messages under error and warning
conditions messages are generated that provide a general status indication of
the execution of the stack.
|
|
DEBUG_VERBOSE
|
This setting is a superset of the above three settings. In
addition to debug messages for all the above conditions, extensive messages
are printed out with as much information for the user as would be required
for deep debugging.
|
|
Remarks
|
·
As the debug level increases from DEBUG_NONE to DEBUG_VERBOSE,
the code memory occupied by the library as well as the CPU utilisation by it increase.
·
It is recommended to set the level to DEBUG_ERROR in the
release version of your product. This will help catch errors in the field.
|
|
|
|
|
Back to the top
|
Macro name
|
DEBUG_COLSIZE
|
|
Description
|
When DEBUG_LEVEL is set to DEBUG_VERBOSE, the length of
debug messages could become too large. This macro can be used to limit the
no. of characters per debug message.
|
|
Permitted Values
|
32 to 132
|
|
Remarks
|
·
This macro is useful in ensuring that the debug messages fit
the column size of your output device (e.g. some printers have 64 character
column width while larger ones have 132 characters)
|
Back to the top
|
Macro name
|
CRC_TABLE_LOCATION
|
|
Description
|
This macro is used to control the manner in which the CRC
tables are created and stored in the library thereby optimising the use of
code and data memory.
|
|
Permitted Values
|
CREATE_DYNAMIC
|
CRC tables are created dynamically during runtime and not
pre-created and stored in RAM or ROM.
|
|
IN_RAM
|
CRC tables are created once at the start of the program
and stored in data memory (RAM).
|
|
IN_ROM
|
CRC tables are stored in code memory (ROM) as a const
array.
|
|
Remarks
|
·
This macro is used only in MODBUS RTU mode.
·
The CREATE_DYNAMIC setting saves both data and code memory at
the cost of lower performance during runtime since the CRC tables have to be
created for every Modbus packet received.
·
The IN_RAM setting saves ROM (code memory) at the cost of using
more data memory. Access to the CRC tables could be faster since RAM access
is faster than ROM access.
·
The IN_ROM setting saves RAM (data memory) at the cost of using
more code memory.
|
|
|
|
|
Back to the top
|
Macro name
|
CRC_TABLE_LOC_MODIFIER
|
|
Description
|
This macro is used to set the keyword that will cause
constant variables in code memory (ROM).
|
|
Permitted Values
|
The keyword used for forcing constant variables into code
memory. E.g. the keyword ‘const’
|
|
Remarks
|
·
Many compilers by default may store constant variables in code
memory. If so, set this macro to a blank.
|
Back to the top
|
Macro name
|
DATA_IN_XRAM
|
|
Description
|
This macro is used to set the keyword that will cause
variables to be placed in external memory.
|
|
Permitted Values
|
The keyword used for forcing constant variables into code
memory. E.g. the keyword ‘xdata’
|
|
Remarks
|
·
Microcontrollers have internal RAM (sometimes in the form of
on-chip registers) and external RAM (also on-chip but not a part of the MCU
core). This keyword is used to force program variables to be placed in the
external RAM.
·
The location of program variables also depends on the memory
model of setting of the compiler. For instance a large memory model
could by default place all program variables in external ram in which case
this macro setting becomes irrelevant.
·
The library uses this macro to modify the location of transmit
buffer and the receive buffer since they form the major component of memory
usage by the library. All other variables used in the library are placed in
the default memory type defined by the memory model setting.
|
Back to the top
|
Macro name
|
MAX_NETWORKS
|
|
Description
|
This macro must be set to the maximum number of
communication channels that the library will communicate on.
|
|
Permitted Values
|
1 to a reasonable maximum value.
|
|
Remarks
|
·
The library allocates as many sets of global variables as the
value of this macro.
·
The actual number of channels used for communication may be
less than this value.
|
Back to the top
|